Changelog for Online Update no. 4
Installation
Software update
Bugfixes and features - released on 18.03.2020
-
Update to patch level 10 4
-
IX-7451: OutOfMemory message when importing very large applications
-
IX-7014: Data Picker in Share does not populate the data record correctly
When people are mentioned in a Share post via "@Name", the last two characters were cut off.
-
IX-7025: Email attachment
When sending summary emails whose content is taken from a free layout table,
attachments are not sent with the emails.
-
IX-6901: No error message for an error during a portal export due to too little memory
If a portal is exported to a medium without enough memory, a corresponding
error message is not shown.
-
IX-7187: Search in the Online Help
When searching in the Online Help, the file "_index.html" is shown as a result.
-
IX-6867: "Basic" file control - Successfully deleting a button via "X" not visible to users
When a user deleted files via the "X" button in a file control ("Basic" template),
the user could not see this.
-
IX-6866: Filewalker - Options tooltip not visible
-
IX-6864: Gauge control - Reload on start page does not work correctly
-
IX-6863: File upload in TinyMCE
In the TinyMCE editor, users could upload files/images even though the "Enable file upload" option
was deactivated.
-
IX-6856: Flickering display in the calendar grid
When users clicked on the calendar grid, it caused the display to flicker.
-
IX-6837: Display error of default values in the binding
If a page contained multiple integer edit fields but a default value was defined for only
one of them, the default value was displayed in all edit fields in some cases.
-
IX-6824: Search suggestions "hang" above the edit field
If search suggestions were activated in an application with a search control,
the suggested terms were not shown correctly in the browser.
-
IX-6823: System fields could be overwritten
-
IX-6786: Solr blocks files
When a file control was added to an application and the file field was included in the search,
an error occurred if a user swapped the file shortly after saving it and saved it again.
-
IX-6768: Processes with "Include processes" cannot be imported
If a process contained an "Include processes" action, the process could not be imported.
-
IX-6767: Small changes to an application generate numerous entries in the history
-
IX-6746: "Organization" cannot be resolved in a process
If the value "Organization" was selected in a filter condition in a process, errors
occurred when saving.
-
IX-6713: Old <entries> elements in distribution controls prevent publishing
-
IX-6682: Tooltip is not shown correctly in the mobile view.
In the "myIntrexxMobil" demo portal, the tooltip for creating news was
not fully shown in the mobile view.
-
IX-6649: Breadcrumb generates a link to a menu container with no link destination
-
IX-6643: Menu separators do not work correctly
If a separator was added to the menu, the separator was shown in the menu twice.
-
IX-6619: Images are not embedded in HTML snippets but linked in PDF documents
If a user-generated PDF documents with pages that contain HTML, which was loaded via
TinyMCE, then the internal images were not shown in the final document.
-
IX-6613: Fortinet firewall raises the alarm when opening myIntrexx
-
IX-6601: Portal Manager crashes when importing applications on macOS Mojave
-
IX-6595: Share feeds cannot be found in the global search
-
IX-6587: Different patch levels between the Portal Manager and Portal Server are not shown
If the Portal Manager and Portal Server have different versions, their version was shown but
not their patch level.
-
IX-6584: "Optimized publish" for applications does not save changes
-
IX-6574: Error when patching email actions
An error could occur in a process with a loop connection between a filter condition and an email action.
-
IX-6566: Users can no longer use the keyboard to page through the results list of a Data Picker.
-
IX-6565: Calendar entry tooltips are outside of the visible area
-
IX-6560: Image from "Image URL" does not show the graphic in its full size
-
IX-6546: Buttons do not work as download links in some circumstances
-
IX-6540: Value range filter filters the date incorrectly
If the start and end date were the same, the date was filtered incorrectly.
-
IX-6531: ID of the additional control "Search" cannot be changed.
The ID of the additional control "Search" could not be changed. This could lead
to layouts no longer being openable.
-
IX-6504: Groovy script
Custom library cannot be loaded
Benutzerdefinierte Bibliothek kann nicht geladen werden
-
IX-6458: "Check the application for errors..." message in the footer
If a user added more than 15 controls to an empty application,
the message "Check the application for errors..." was shown multiple times in the footer.
The message is now only shown once.
-
IX-6430: Cannot jump to an application
If the start page of an application was defined as a portlet, the link in the menu
to the same page did not work anymore.
-
IX-6428: Error message when adding a FileWalker control
-
IX-6426: Cannot jump to a data group via the search
-
IX-6421: Errors when importing applications with gauge controls
-
IX-6411: Burger icon does not reliably close the menu
-
IX-6407: Rotated views for the resource calendar do no generate a request parameter for preallocating
the resource
-
IX-6405: When opening the "Annual report" page in the "Statistics" application, a Velocity syntax error occurs
The error did not occur if the portal is new; existing applications needed to be adjusted.
-
IX-6377: The right field of the multiple selection element was sometimes displayed to large.
-
IX-6357: Read/WriteContainers - Fallback value und Velocity code
If "Velocity" was selected as the fallback value on the "Parameter" tab of a button,
a new line could not be begun without the properties dialog closing.
-
IX-6299: Refresh tables when closing a tooltip
When closing a tooltip, only one table was refreshed instead of multiple tables.
-
IX-6293: Selecting "Same page" when creating a template, does not function as expected
When the destination "Same page" is selected when creating a template for control elements, the
original page, meaning where the control element was created, is interpreted as the "Same page".
In addition, the WriteContainer needed to be reselected every time the template was used.
-
IX-6280: Not possible to publish applications after importing a portal
In some circumstances, it was not possible to publish applications after importing
a portal even though the import was error-free.
-
IX-6272: Application cannot be published after moving a radio button group to the hidden area
-
IX-6222: In the "Task scheduler" in the Portal Manager, repetitions cannot be entered for a file index job.
-
IX-6217: The photos of inactive users are not synchronized correctly with the Active Directory
-
IX-6200: "Suggester maintenance" index job faulty
If the schedule of the "Suggester maintenance" index job was adjusted, an error occurred.
This meant that the "Task scheduler" could not be started in the Portal Manager.
-
IX-6175: Error message when deleting "myIntrexx Portal"
In specific constellations, a stack overflow exception occurred when deleting portals.
-
IX-6108: Tagging control does not accept hashtags
If a user entered a hashtag in a tagging control, this was deleted when the user
pressed the spacebar (to enter the next tag).
-
IX-6099: Tooltip opened from a table leaves space after it is closed
If a view page is opened from a table with the destination option "Open in grouping" >
"Beneath the current table row]" and then closed via the "Close tooltip" button,
then the space created for the tooltip remained.
-
IX-6016: Users can delete portlets despite having no permission to do so
-
IX-5984: In special constellations, users can delete portlets of other users
-
IX-5932: Portal service cannot be started on Mac
-
IX-5907: "Calculation" element applies the "Formula prefix" and "Formula suffix"
to other "Calculation" elements.
-
IX-5892: Link dialog for buttons allows non-permissible configurations
If a button jumps to another view page, then a non-permissible configuration
was generated ("Create new data record"). The Portal Manager behaved in a similar
manner if the button was initially configured to jump to an edit page with
"Create new data record" and the jump was then changed to a view page.
-
IX-5835: Filter in a dependency cannot be opened
-
IX-5818: Charts - Special characters in the value for the rows cause errors
If the data field used for the rows contains special characters, such as 'ยง', the
diagram was not displayed.
-
IX-5440: Report buttons open in a new window even though "Open in new tab"
was selected in the properties dialog.
-
IX-5326: Portal Manager stops on inactive link destination option
-
IX-5272: Strange behavior when importing an application package
-
IX-4840: Close tooltips with Escape
In some circumstances, tooltips could be closed with Escape even though
this should not have been possible (closeByEsc: false).
-
IX-4429: Errors occur when uploading and cropping images
-
IX-3801: Filters do not function correctly with the French number format
-
IX-1780: Fuzzy Roboto font in Chrome